Lane5000 error on manual entry with FDMS: The mathematical check (luhn/mod10) on the account number has failed

Home » Categories » Multiple Categories

Lane5000 error on manual entry with FDMS: The mathematical check (luhn/mod10) on the account number has failed

Summary:

Lane5000 error on manual entry using FDMS as processor: The mathematical check (luhn/mod10) on the account number has failed.

Cause:

The Lane 5000 is running an older version of firmware that had a known issue using manual entry with First Data. The firmware needs to be updated to at least 6.50.01

 

 

 

Solution:

Update firmware on Lane 5000 to 6.50.01 (or higher):

Ingenico UPP v6.50.01 Firmware Update (ncrcounterpointhelp.com)

 

Tracking Information:

WIT# CP-9802
Found in:
Fixed in:

Attachments Attachments
There are no attachments for this article.